What can cause this symptom
- Air Only, Air Fluff, Cool, or another non-heated setting is selected.
- An electric dryer has enough 120-volt power to tumble but has lost the full 208/240-volt supply needed for heat.
- A gas dryer has no fuel supply, an interrupted utility or LP supply, or another ignition/heating condition.
- Restricted airflow or a blocked vent is extending drying or causing heat protection to operate.
- An internal heater, thermal device, ignition component, sensor, control, or wiring condition requires service.
Safe checks in order
- 1
Confirm the symptom
- Verify that the drum actually tumbles and that there is no warmth after a manufacturer-supported heated test. A no-start condition belongs to a different diagnostic path.
- If there is some warmth but drying is slow, also inspect the lint filter, load, and accessible exhaust path; airflow is not proof of a failed heater.
- 2
Check the cycle and options
- Select a normal heated or timed-dry setting supported by the model. Air Only, Air Fluff, and Cool settings intentionally provide no heat.
- Allow for model features such as LG Energy Saver, which can begin with an extended no-heat period.
- 3
Identify electric or gas without moving the dryer
- Use the model label, owner’s manual, or visible installation information. Do not pull out a connected dryer merely to inspect behind it.
- Apply only the fuel-specific branch below.
- 4
For an electric dryer: reset the supply once
- An electric dryer may tumble on one 120-volt leg while the heater lacks the full 208/240-volt supply. At the electrical panel, move the dryer’s paired/double breaker fully OFF and then ON once if it is dry, undamaged, and safe to access.
- Stop if it trips again. Do not remove terminal covers, open panels, test live voltage, or repair wiring; use an electrician or qualified service.
- 5
For a gas dryer: observe only
- If there is no gas odor, compare the externally visible gas-supply position and fuel availability with the exact installation instructions; interruption of natural gas or an empty LP supply may prevent heat.
- Do not loosen fittings, move the dryer, relight, test for leaks, or repair gas components. Any gas odor triggers the emergency instructions above.
- 6
Check only accessible airflow items
- Clean the lint filter and inspect an accessible exterior outlet for obvious blockage only when the exact manual permits it.
- Do not disconnect hidden ducting or continue repeated cycles. A passed vent check with no heat points to service on brands such as Samsung.
Brand and model differences
- LG distinguishes true no heat from long drying and documents Energy Saver and installation-test behavior; its gas-odor instructions require leaving the area and contacting the gas supplier.
- Samsung notes that severe vent restriction can suppress heat, but directs service when its vent test passes and the dryer still does not heat.
- GE explains that an electric dryer can tumble on 120 volts while needing 208/240 volts for heat; this guide excludes GE’s terminal-block inspection because it crosses the homeowner-safe boundary.
- Whirlpool and Maytag both document heated-cycle selection, the two-breaker electric supply, gas supply, and professional diagnosis of internal heating parts.
- Bosch directs a dryer that is not warming to support; Bosch E06 identifies a heating-circuit fault for an authorized technician.
- Frigidaire distinguishes electric dual-circuit supply from gas-supply checks and recommends an electrician verify 240-volt power.
Actions not recommended
- Do not replace an element, fuse, igniter, valve, or board from the symptom alone.
- Do not probe a 208/240-volt circuit or remove a terminal or appliance panel.
- Do not loosen gas connections, use a flame to check for leaks, or attempt ignition repair.
- Do not repeatedly run the dryer with severe vent restriction or an unresolved safety warning.
When to request service
- The dryer tumbles but remains cold after a documented heated setting and the appropriate external supply check.
- A breaker trips again, the outlet or cord appears damaged, or qualified voltage verification is needed.
- Gas supply is available but there is no heat, or any gas component would need inspection.
- A code returns, a vent test passes with no heat, or the next step requires panels, instruments, internal wiring, or heating components.
Official manufacturer sources
- LG USA SupportNot Heating, Not Drying or Long Time Drying ↗
- LG USA SupportWhat to do if you smell gas around your LG dryer ↗
- Samsung SupportSamsung dryer will not heat or does not heat enough ↗
- GE AppliancesElectric Dryer - Runs But Does Not Heat ↗
- Whirlpool Product HelpDryer is Not Heating ↗
- Maytag Product HelpDryer is Not Heating ↗
- Bosch Home AppliancesDryer not getting warm ↗
- Bosch Home AppliancesBosch dryer error codes ↗
- Frigidaire Owner SupportMy dryer is running but does not seem to be heating ↗
Reviewed: August 29, 2026.